Below are the scanned copy of Kerala Public Service Commission (KPSC) Question Paper with answer keys of Exam Name 'OVERSEER/ DRAFTSMAN GR II ELECTRICAL NCA OBC PUBLIC WORKS/IRRIGATION' And exam conducted in the year 2015. And Question paper code was '274/2015'. Medium of question paper was in Malayalam or English . Booklet Alphacode was 'A'. Answer keys are given at the bottom, but we suggest you to try answering the questions yourself and compare the key along wih to check your performance. Because we would like you to do and practice by yourself.

page: 10 out of 11
Excerpt of Question Code: 274/2015

D:-vibration
Correct Answer:- Option-B
Question87:-The frequency of electricity supply in India is
A:-60 Hz
B:-45 Hz
C:-55 Hz
D:-50 Hz
Correct Answer:- Option-D
Question88:-The size of copper plate used in plate earthing system is
A:-60 cm x 60 cm x 3.15 mm
B:-60 cm x 60 cm x 6.3 mm
C:-30 cm x 30 cm x 3.15 mm
D:-60 cm x 60 cm x 3.3 mm
Correct Answer:- Option-A
Question89:-One Webber is equal to ____ Maxwell.
A:-10000
B:-100000
C:-10000000
D:-1000000
Correct Answer:- Option-C
Question90:-The standard secondary out put of a current transformer is
A:-10A
8:-5&
೧7೩
D:-3A
Correct Answer:- Option-B

Question91:-In two watt meter method of power measurement one watt meter shows negative reading the power factor of
the load

A:-unity
B:-bellow 0.5 lagging
C:-0.8 lagging
D:-in between 0.5 and 0.8 lagging
Correct Answer:- Option-B
Question92:-The working principle of earth tester is
A:-Fall of potential method
B:-Wheatstone bridge principle
C:-Voltage divider method
D:-Meter bridge principle
Correct Answer:- Option-A
Question93:-The polarity of interpole is in the case of DC generator and motor is
A:-same as next main pole ahead in the case of motor and generator in the direction of rotation

B:-same as the next main pole behind in the case of motor and generator in the direction of rotation of motor and
generator

C:-same as next main pole behind in the case of generator and next main pole ahead in the motor in the direction of
rotation

D:-same as next main pole behind in the case of motor and same as next main pole ahead in the generator in the
direction of rotation

Correct Answer:- Option-D
Question94:-The distance between earth electrode and adjacent building should not less than

ಹಿ2ಗಾ

B:-1m

6:576

0:-1.5 0

Correct Answer:- Option-D
Question95:-Type of cooling used in Distribution transformer is

ക്ഷ്‌

B:-AN, OFN

C:-0B, AB

D:-AN, ON

Correct Answer:- Option-D