Below are the scanned copy of Kerala Public Service Commission (KPSC) Question Paper with answer keys of Exam Name 'OVERSEER/ DRAFTSMAN GR II ELECTRICAL NCA OBC PUBLIC WORKS/IRRIGATION' And exam conducted in the year 2015. And Question paper code was '274/2015'. Medium of question paper was in Malayalam or English . Booklet Alphacode was 'A'. Answer keys are given at the bottom, but we suggest you to try answering the questions yourself and compare the key along wih to check your performance. Because we would like you to do and practice by yourself.

page: 9 out of 11
Excerpt of Question Code: 274/2015

Question77:-The purpose of bedding provided in cable is
A:-Protect the cable from mechanical injury
B:-Protect the cable from atmosphere
C:-Protect metallic sheet from mechanical injury
D:-Prevent entering moisture to the cable
Correct Answer:- Option-C
Question78:-Silver plated mica capacitors are best suited for_____ application.
-High frequency application
B:-High voltage application
C:-Radio frequency application
D:-Power factor correction
Correct Answer:- Option-A
Question79:-When Dynamo meter type meters are used as watt meters, the fixed and movable coils are
:-Fixed coil 5 pressure coil and moving coil is current coil
B:-Fixed coil is current coil and moving coil 5 pressure coil
C:-Both coils are movable
D:-Can be ammanged as either cument coil is fixed and pressure coil movable and vice-versa
Correct Answer:- Option-B

Question80:-A 50 volt meter want to be extend to measure 250 volt meter. The resistance of the meter is 5000 Q, what will
be the value of multiplier required

A:-40000 Q
B:-20000 Q
C:-50000 Q
D:-25000 Q
Correct Answer:- Option-B
Question81:-The instrument used for measuring insulation resistance of equipments is
A:-Contact resistance meter
B:-Earth tester
C:-Ohm meter
D:-Megger
Correct Answer:- Option-D
Question82:-Among the following which cable is used for Railway signaling purpose
A:-PVC cable
B:-Lead sheet cable
C:-Torpodure cable
D:-Armed cable
Correct Answer:- Option-C
Question83:-In Geyser the type of insulation provided in between the inner and outer chamber ‏كا‎
‎A:-Mica

B:-Rubber
C:-Glass wool
D:-Asbestose
Correct Answer:- Option-C
Question84:-Among them which material is shows strong Dia magnetism
A:-Copper

D:-Aluminum
Correct Answer:- Option-C
Question85:-Ear to Ear resistance of wet human body is about
A:-100 ohm
B:-150 ohm
C:-400 ohm
0:-300 70
Correct Answer:- Option-A
Question86:-The major cause of creeping error in induct in type energy meteris
A:-Over voltage
B:-Over compensation friction
C:-Stray magnetic field