Kerala PSC Previous Years Question Paper & Answer

Title : VOCATIONAL TEACHER MAINTENANCE AND REPAIRS OF DOMESTIC APPLIANCES VHSE
Question Code : A

Page:6


Below are the scanned copy of Kerala Public Service Commission (KPSC) Question Paper with answer keys of Exam Name 'VOCATIONAL TEACHER MAINTENANCE AND REPAIRS OF DOMESTIC APPLIANCES VHSE' And exam conducted in the year 2015. And Question paper code was '225/2015'. Medium of question paper was in Malayalam or English . Booklet Alphacode was 'A'. Answer keys are given at the bottom, but we suggest you to try answering the questions yourself and compare the key along wih to check your performance. Because we would like you to do and practice by yourself.

page: 6 out of 12
Excerpt of Question Code: 225/2015

41

42:

43.



47.

48.

Multiple trace ബേ be accomplished in a CRO with :
(ಹಿ) Horzontal deflection system (8) Compensation adjustment
(C) Dual ‏سوعط‎ CRT (D) Vertical deflection system

In an electronic ohm meter, the OP-AMP is used as a :
(ಗೆ) summer - (B) differentiator
(൫) integrater ۹ (D) buffer सलः

In order to reduce the loading effect of the circuit under test, the input impedance of an
electronic meter should be :

(ಡಿ) 10% (B) 880
(0 medium (D) constant

Electronic volt meters are more accurate for high resistance circuits as compared to ordinary
voltmeter because of its :

(A) high volt/ohm rating (B) high ohm/volt rating
(() high resolution (D) high output impedance

If the duty cyele of a pulse waveform clamped around zero is 0.5, What is its crest factor?
(#) 2.22 © 8
(0 31 D) 19

ங்‌

A digital power factor meter converts pf into frequency and is counted. If the peak stepped
down voltage is 2V, CT ratio 1:40 and rectifier gain is 1. What would be the frequency for
0.85 pf?

(&) 21.65 प्रय ध (B) 43.33Hz
ര 5l44Hz (D) 30.5Hz

The voltage sensitivity of a multi meter is 20mV. Its internal resistance is 40 ohm. Then its
current sensitivity is :

(ಹ) 2 milli ampere (B) 5 micro ampere

(0) 500 micro ampere M) 08A

A digital phase meter with ZCD is fed with 2 sinusoidal voltages of the same amplitude and
frequency but with a phase displacement. If the time delay with them is 0.15 msec and their
time periods are 1.5 msec, what is the measured phase difference :

(4) 36.86 (8) 45°
(C) 85°46' ൬) 180°

225/2015 8 A