Kerala PSC Previous Years Question Paper & Answer

Title : TECHNICIAN GRADE II BOILER OPERATOR KCMMF
Question Code : A

Page:6


Below are the scanned copy of Kerala Public Service Commission (KPSC) Question Paper with answer keys of Exam Name 'TECHNICIAN GRADE II BOILER OPERATOR KCMMF' And exam conducted in the year 2017. And Question paper code was '068/2017/OL'. Medium of question paper was in Malayalam or English . Booklet Alphacode was 'A'. Answer keys are given at the bottom, but we suggest you to try answering the questions yourself and compare the key along wih to check your performance. Because we would like you to do and practice by yourself.

page: 6 out of 11
Excerpt of Question Code: 068/2017/OL

B:-Right side of boiler shell
C:-Bottom of boiler shell
D:-Left side of boiler shell
Correct Answer:- Option-A
Question48:-Where is High-steam low water safety valve used 7
A:-Cochran boiler
B:-Lancashire boiler
C:-Babcock and Wilcox boiler
D:-Locomotive boiler
Correct Answer:- Option-B
Question49:-Which among the following pressure measuring instrument is used 25 a pressure gauge in boiler 7
A:-Bellows
B:-Magnetic coupling
C:-Bourdon-tube
D:-Mc-Leod gauge
Correct Answer:- Option-C
Question50:-What is the function of fusible plug 7
A:-Regulate pressure inside boiler
B:-Supply excess water needed
C:-Check water level
D:-Put-off fire in fumace, as water level fall
Correct Answer:- Option-D
Question51:-What is the function of boiler accessories 7
A:-For operation and safety of boiler
B:-For cleaning and maintenance
C:-For increasing overall efficiency of boiler
D:-Anxiallary part to support boiler
Correct Answer:- Option-C
Question52:-Which among the following boiler accessories preheats boiler feed water 7
A:-Air-preheaters
B:-Economiser
C:-Super-heaters
D:-Water-feeding equipment
Correct Answer:- Option-B
Question53:-Where is air preheater ೧12೧66 ?
A:-After the economiser
B:-In the fumace
C:-Before the economiser
D:-In the chimney
Correct Answer:- Option-A
Question54:-What is/are the advantage/s of super heater 7
It increases specific steam consumption of engines and turbines.
It eliminates the erosion of the turbine blades.
It reduces condensation losses in pipes and engine cylinder.
Efficiency of steam plant is higher.

Correct Answer:- Option-D
Question55:-What are the functions of blow-off cock 7
Empty boiler for cleaning and maintenance purpose.
Supply water to the boiler high pressure continuously.
Prevent the back-flow of water from boiler to pump.
Discharge mud and sediments accumulated at the bottom of the boiler.

Correct Answer:- Option-C

Similar Question Papers

Ask Question

(Press Ctrl+g to toggle between English and the chosen language)


Questions & Answers