Page:5
Below are the scanned copy of Kerala Public Service Commission (KPSC) Question Paper with answer keys of Exam Name 'SUB ENGINEER' And exam conducted in the year 2015. And Question paper code was '016/2015/OL'. Medium of question paper was in Malayalam or English . Booklet Alphacode was 'A'. Answer keys are given at the bottom, but we suggest you to try answering the questions yourself and compare the key along wih to check your performance. Because we would like you to do and practice by yourself.
C:-Low
D:-Very low
Correct Answer:- Option-C
Question39:-in core type transformers the number of flux paths are
൧-2
B:-more than 2
C:-Half of the path
D:-single
Correct Answer:- Option-D
Question40:-The relation between the excitation current and magnetic flux of a transformer is
A:-Current leads flux
B:-Flux leads the current
:-They are in phase
D:-None of the above
Correct Answer:- Option-A
Question41:-The equivalent resistance and leakage reactance of a transformer can be found out by
A:-Open circuit test
B:-short circuit test
C:-polarity test
D:-None of the above
Correct Answer:- Option-B
Question42:-Hydro generator is the commercial name of
A:-Round rotor generator
-Cylindrical rotor synchronous generator
C:-Salient pole synchronous generator
D:-All the above
Correct Answer:- Option-C
Question43:-An electrical machine with lower efficiency will have
A:-Less losses
-More losses
C:-No losses
D:-Low operating cost
Correct Answer:- Option-B
Question44:-The effect of armature reaction under the pole shoes can be limited by
A:-Inter poles
-High reluctance pole tips
C:-Compensating windings
D:-All the above
Correct Answer:- Option-C
Question45:-DC motors are started by using starters because
A:-To increase the starting current
B:-To reduce the staring current
C:-To increase the speed
D:-none of the above
Correct Answer:- Option-B
Question46:-Swinburne 's test can not be performed on
A:-Shunt motor
B:-compound motor
C:-series motor
D:-All the above
Correct Answer:- Option-C
Question47:-which of the following are used as constant speed drive
A:-Dc shunt motor
-DC series motor
C:-DC compound motor
D:-All the above
Correct Answer:- Option-A
Question48:-No load slip of an induction motor is
A:-Large